Difficult Pump Application/Selection 3 Months, 3 Weeks ago Karma: 0  
I am having some trouble finding a supplier or manufacturer that can supply a pump for an application.

The situation is as follows;
We use non-clog trash pumps made of alloy-20 (50TDH, 600GPM) on an effluent application. The pumps are located below grade, are in a confined space, flood when it rains hard, and are no longer resonably available. (30-36 wks)

Ideally I want to find a pump manufacturer that can supply a self-priming non-clog trash pump constructed of alloy-20 or hastalloy-c.

Any suggestions?
Thanks
Enter code here   
Please note, although no boardcode and smiley buttons are shown, they are still useable
 
Report to moderator   Logged Logged  
  Reply Quote
#18
Norvicute (User)
Junior Boarder
Posts: 24
graph
User Offline Click here to see the profile of this user
Gender: Male Mechanical Engineer Forum Location: Saudi Arabia
Re:Difficult Pump Application/Selection 3 Months, 3 Weeks ago Karma: 0  
Hi there Jason and to all as well.

If you would need a self priming non-clog trash pump, there are some manufacturer that can supply your requirement.

Were currently using a trash hog type pump which is basically good in handling slurries and solids and the pump is a self priming as well.

You can search for a "trash hog" on your net and you will see several manufacturer.

You did not specify the unit of your TDH I guess that was in feet. If that is in meters your TDH would be too high for a self priming non-clog.

Please let me know if I can help further.

Enter code here   
Please note, although no boardcode and smiley buttons are shown, they are still useable
 
Report to moderator   Logged Logged  
 
  Reply Quote
#20
Norvicute (User)
Junior Boarder
Posts: 24
graph
User Offline Click here to see the profile of this user
Gender: Male Mechanical Engineer Forum Location: Saudi Arabia
Re:Difficult Pump Application/Selection 3 Months, 3 Weeks ago Karma: 0  
Enter code here   
Please note, although no boardcode and smiley buttons are shown, they are still useable
 
Report to moderator   Logged Logged  
 
  Reply Quote
#23
njjicheng (User)
Fresh Boarder
Posts: 2
graphgraph
User Offline Click here to see the profile of this user
Re:Difficult Pump Application/Selection 3 Months, 2 Weeks ago Karma: 0  
Seek help

Hello,
our plant will revamp super high BFW system, and need add a new BFW feed pump. At present, there are three pumps in this system, one is motor drived,two are drived by turbine. normally, two run, one standby. Normal flow of every pump is 170M3/h, and the dischaige pressure is 15Mpa, the temperature is 120. now , the problem is we can not find a duplicate to existing pump and we add a different pump will bring what result, whether it will cause unstable or other situations? the textbook said it is not recommendated two different pumps work together. in addition , I aslo consult some power plant engineers , they also held same opinions , BFW feed pumps in most of PP are produced by same manufacturer.
So, I would like to seek some expert to clear my confusion and give some comments for this matter.
For further communication, you can send E-mail to This e-mail address is being protected from spam bots, you need JavaScript enabled to view it , I am looking forward to hearing you .

Thanks!
Enter code here   
Please note, although no boardcode and smiley buttons are shown, they are still useable
 
Report to moderator   Logged Logged  
  Reply Quote
#24
Norvicute (User)
Junior Boarder
Posts: 24
graph
User Offline Click here to see the profile of this user
Gender: Male Mechanical Engineer Forum Location: Saudi Arabia
Re:Difficult Pump Application/Selection 3 Months, 2 Weeks ago Karma: 0  
Hi njjicheng ,

If your going to run the additional pumps in parrallel with the existing, you cannot have different pump otherwise you have to provide the pump curve to the manufacturer for them to have proper selection. This is important.

Have you check with me OEM (original equipt. mfg). If they already discontinued the pump model they might have a replacement one.

Since you have mentioned that your plant will revamp a high BWF system. There would be changes on your operating conditions. Does the existing pumps can perform well on that changes? You have to check with your OEM.

Please let me know if I can help further.

Enter code here   
Please note, although no boardcode and smiley buttons are shown, they are still useable
 
Report to moderator   Logged Logged  
 
  Reply Quote
#25
njjicheng (User)
Fresh Boarder
Posts: 2
graphgraph
User Offline Click here to see the profile of this user
Re:Difficult Pump Application/Selection 3 Months, 2 Weeks ago Karma: 0  
Dear Norvicute,

The BFW system revamping of our plant is based on wholly plant expansion, just only need add a new pump to parallel with other three pumps, the design operation model will be three pumps running and one standby.
Just as you mentioned, we checked OEM and expected data sheet for revamped plant and found the shortage is less than the normal flowrate of one exsiting pump,only it is 60% of the latter. So new issue arising, which is better, add a same capacity pump or add a samller pump. The operating conditons will be change if add a same capacity pump. But adding a small pump is also not a good option, I think.

Appreciate your feedback.