Diaphram Pump Priming (1 viewing) (1) Guest
Go to bottom Post Reply Favoured: 0
TOPIC: Diaphram Pump Priming
#3
coco (User)
Fresh Boarder
Posts: 1
graphgraph
User Offline Click here to see the profile of this user
Diaphram Pump Priming 3 Months ago Karma: 0  
I have a diaphram pump used to pump water into my house. I recently had to replace the pressure switch (pre-set 30psi on - 50psi off). When I replaced the switch, the pressure in the diaphram tank dropped to about 15-20 psi. I turned the pump back on and now the pump cycles constantly while running water in the house. I read where I should have "primed" the tank to 40 psi first. Ok, what's the best way to have it cycle normally again? Is the correct porcedure to
1). Turn off water to the pump.
2). Turn off electricity to the pump.
3). Open all the faucets, showers, etc to drain out the water and relieve pressure in the lines, and then close them all back.
4). With lines now empty, prime the tank to 40 psi
5). Turn back on water to the pump.
6). Turn back on electricity to the pump.
Thanks for any help any of you might have.
Enter code here   
Please note, although no boardcode and smiley buttons are shown, they are still useable
 
Report to moderator   Logged Logged  
  Reply Quote
      Topics Author Date
    emo
Diaphram Pump Priming
coco 2008/05/08 05:59
    thread link
thread linkthread link Re:Diaphram Pump Priming
Mivos 2008/05/13 03:33
Go to top Post Reply