Hi,
Yes you should check the correct impeller trim required. If problem is same. You may check the following:
a. Check the impeller wear rings and impeller setting, it may be worn out or the impeller is not properly set.
b. You may also check the flow meter and the check valve if still ok.
c. Check the driver as well. I mean the rotation if correct, motor speed if you are using VFD, voltage condition also.
d. Check the suction pipes etc., there maybe a leak or damage, check air or gas introduction in suction and in stuffing box as well.
You may also check your system head (actual TDH). Review all losses.
Worst is check the pump capability to a parallel operation.
Hope this helps.
give me update.
Otherwise you can provide me a copy of pump curve size and motor rating for me to evaluate the pump.