Motors Controlled by Variable Frequency Drives

Page 1 of 2
Written by:
Jack Creamer, Schneider Electric
max
mid
min

Pumps & Systems, March 2007

Industry analysts predict that in the near future, most motors will be controlled by variable frequency drives. Here are the reasons why. 

VFDs offer energy savings, increased functionality, integration with automated systems, and reduced maintenance, which are increasingly making them the product of choice for motor control. They have evolved significantly over the past 40 years in terms of physical size and weight, as well as in performance, reliability, functionality and cost.

As with other industrial automation equipment, the trend with VFDs continues to be that with each generation: the size, weight and cost decreases while the performance and functionality increases.

Three technologies have influenced the evolution of VFDs. First is the growth of power conversion components, such as transistors, diodes, silicon controlled rectifiers (SCRs), gate turn-offs (GTOs) and insulated gated bipolar transistors (IGBTs). The second technology is the progression of control electronics and performance control algorithms that migrated from analog circuits to digital control through the use of microprocessors. The third area of development is communication connectivity and advanced automation concepts using field customizable algorithms to meet specific application needs, and the integration of Web-based and Internet technologies.

1960s

VFDs came about during the 1960s to support the manufacturing of synthetic-fiber processes in the textile industry. The technology evolved from manufacturers that used DC motors and DC bus systems with simple electronics to control the speed of their motors.

The term "inverters" was used to describe the process of converting the existing DC bus systems to regulate motor speed. However, these early inverters were expensive, and reliability remained a major concern. Components typically had short life cycles that led to frequent and untimely replacement, sometimes resulting in unscheduled downtime and inefficiencies on the manufacturing floor.

1970s through the 1990s

In the 1970s and 1980s, early advancements in semiconductor technology, specifically for power electronic devices, improved semiconductor reliability and led to performance advancements in early VFDs.

The power electronics used in VFDs shifted from SCRs to Darlington transistors in the second power stage. The AC wave form reproduction was limited to a rough sinusoidal six-step output signal. This six-step output signal limited the operation of motors to 85 percent of their rated capacity or required a 1.15 service factor to prevent motor overheating. Low speed operation of the motor also was limited due to a cogging effect below 10 percent rated speed.

Some minor improvements were made with the introduction of the GTO. These power devices allowed a smoother output signal, but were difficult to control. The dilemma facing designers during this period was the trade-off between using semiconductor devices that had fast switching times but were less reliable, or using devices that were more reliable but had slower switching times. This made the use of drives in pumping operations less desirable since users were faced with drives that performed well, but weren't reliable, or more reliable drives that didn't perform as well.

Up to this point, the various algorithms to control the power conversions and AC form reproduction were accomplished using algorithms solved by extremely complex analog circuitry, which also added to the reliability concerns.

Then, in the late 1980s and early 1990s, VFDs shifted from analog to digital control with the implementation of microprocessors. The microprocessors dramatically improved their performance by enhancing the timing schemes of back-end devices such as GTOs. About the same time, improvements in semiconductor technology lead to the introduction of IGBTs.

The advancement in semiconductor manufacturing soon led to miniaturization and integration of multiple IGBTs into a single package. This dramatically reduced both the size and cost of the VFDs, while improving their thermal characteristics. With the use of microprocessors and IGBTS, the reliability concerns that limited the acceptance of drives in the past began to quickly dissipate.

During this same period, energy conservation became a hot topic to manufacturers as they sought ways to reduce energy costs. With reliability concerns being a thing of the past, the cost of VFDs being driven down, and the increasing interest in energy conservation, VFDs rapidly gained acceptance in a variety of new industries and applications outside of the traditional industrial process control applications. With pump applications consuming a large percentage of all electrical energy consumption, they became a target for variable torque loads drives installations and retrofits.

Further improvements to microprocessor design and computational speed performance soon allowed VFD designers to develop control algorithms that maximized the physical switching characteristics of IGBTs. This led to better control and performance of pulse width modulation (PWM) techniques.

New levels of microprocessor speeds then allowed VFDs to process additional feedback and paved the way for newer and improved techniques such as flux vector control with encoder feedback. This, in turn, led to modern methods such as sensor-less flux vector control and other advanced motor performance in torque generation and speed control. These developments reduced the concerns associated with harmonics and power factor correction, and opened the door for VFDs to even more applications.

By the mid-1990s, as VFDs became widely used, requests by users for network connectivity become more common. As a result, higher-end VFDs evolved to include the capability to connect to, and be controlled over most of the commonly used industrial and building automation networks. The ability to connect over various networks, and retrieve performance and diagnostic information increased VFD use exponentially. In addition, this greatly simplified installation, start-up and troubleshooting of VFDs.

The New Millennium

The popularity of VFDs grew in the early 2000s, along with advancements in microprocessor and Web-based technologies. Among the higher-end versions, VFDs today can be connected over an Intranet to serve Web pages up to a computer using a standard Internet browser for monitoring and configuring purposes. Other Web-based technologies have been implemented as well, including the ability to send out email and text messages in the event of an alarm or other fault. 

VFDs continue to undergo transformations. More recently, they've seen increased microprocessor memory that allows modification of various control algorithms or generic functions,

max
mid
min


© Copyright Cahaba Media Group 2012. All Rights Reserved. Privacy Policy | Terms & Conditions