What Determines Seal Leakage?


Written by:
Fluid Sealing Association

The purpose of a mechanical seal is to prevent leakage but all seals leak to some controlled degree. However, it is important to note that this minimal leakage can be so restricted that specific designs are capable of adequately meeting all emission requirements. Seal failure is defined as excessive leakage. The seal can be described as a controlled leakage device represented by two nonporous, plane, parallel walls separated by a distance h, the seal face separation. Assuming constant physical properties and laminar, incompressible flow, the leakage rate is proportional to the pressure and to the cube of the face separation.

As should be expected, large seals tend to leak more than small seals. In theory, leakage would be greater for a narrow face seal than for a wide face seal, but in practice, narrow face seals often leak less because the sealing gap for narrow faces is usually less than for wide faces.

 

Seal Face Separation

The seal face separation, h, cannot be easily calculated, but is the same order of magnitude as the combined surface roughness of the primary ring and mating ring. The sustainable minimum face separation is limited by the friction, wear and lubricating properties of the material pair and fluid. In practice, this gap is affected by many parameters including face flatness, load, viscosity and speed; it can easily vary from 5 to 50 microinches or more. Specifications often require flatness within two helium light bands (23 microinches). During operation, distortions may easily produce deviations from flatness of ten light bands or more. For these reasons, leakage rates can vary considerably from seal-to-seal, test-to-test, or even day-to-day.

Face Treatments

Various face treatments can be applied to the sealing faces such as slots, grooves, waviness or special lapping processes. These treatments are designed to enhance lubrication and increase hydrodynamic lift, which in turn reduces seal face friction. This increases the film thickness between the seal faces. They are primarily used in two situations:

a) Liquids with poor lubricating qualities

b) Heavy face loads relative to the load bearing quality of the seal face materials

In using face treatments in light hydrocarbons and other services where vaporization occurs between the seal faces, a high balance ratio is required to maintain face contact and minimize leakage. 

Principal Leakage Factors

Often seal face leakage rates will depend on pump/motor operating conditions. If operating vibration levels are high, the shaft suffers from excessive radial or axial movement or is misaligned excessively, leakage rates tend to be higher.

Typically, seals leak more during dynamic operation than in a static condition under fluid pressure. During shaft rotation, a fluid film develops between the seal faces to separate them with a larger gap, which causes higher leakage. In a static condition, the faces physically contact each other and have nil leakage. An exception can be standby seals that have previously been run dynamically. The dynamic operation may establish a non-flat face pattern, as shown in Figure 1, which may leak more than when the seal is running.

 

Figure 1. Distortions

Under steady state operating conditions, a typical face seal will contact and gradually wear in. The leakage rate at start-up tends to be higher than when the seal is worn in, particularly with hard face material combinations. The wearing process changes the face profiles to compensate for the seal face pressure and thermal distortions and affects the seal face surface finish. If wear is severe, the surface finish can become rough and the leakage will increase. Abrasives in the sealed fluid can destroy the seal face surface finish in a short time. Some applications have material film transfer between the faces. If the material built-up on the face is not uniform, it can cause higher leakage. 

Load

If the loading conditions change, the worn faces will start another wear transition. Sometimes, the faces have been badly worn and excessive fluid pressure opens them under the new loading condition. This can lead to uncontrollable leakage. To survive changing operating conditions, the seal can be designed to avoid contacting wear but with a controllable consistent leakage. A hydrostatic coned face seal is a design example. This type of seal will leak one order of magnitude higher than conventional contacting face seals. More advanced non-contacting non-leaking seal designs have also proven feasible, but have limited application range.

Leakage Sources

In most cases, the seal leakage comes from the sealing interface. However, in some situations, leakage may come from the secondary sealing area, such as O-rings. This could be due to O-ring degradation caused by chemical attack, overheating and loss of resilience from compression set. In rare occasions, the sealing rings are porous and fluid leaks through the bodies. The above leakage problems can be identified with static pressurization.